Lg Neo Plasma Error Codes C5

Contents

HighOutdoor Status = OffError Code = 63Contents = Cond. Check to earth 50 MOhm minimum, check run current 23 Inverter dc voltage low. Multi V - also check Sub outdoor unit dipswitch settings CH52 Communication error between inverter PCB and main outdoor unit PCB. If OK replace PCB, if not replace sensor 137 Sub 2 outdoor unit liquid pipe sensor fault. http://globalinfoindex.com/error-code/lg-plasma-error-codes.php

If there is no voltage, the indoor PCB is faulty 3. If you see fault code CH07 only type 7 in your text message 18 no such fault code Text 1, 2 or 3 digit fault code number only. Miguel Padierna 22.966 görüntüleme 1:21 Split LG Hero Inverter 8500 BTUs em funcionamento - Süre: 2:22. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. http://www.fixya.com/support/t8080226-lg_neo_plasma_s12ahn_c5_displayed

Lg Inverter Air Conditioner Error Codes

Disconnect from PCB measure resistance 237 kOhm at 20C and 168 kOhm at 30C.if not replace sensor 164 Sub 3 outdoor unit coil sensor A fault. If OK change outdoor inverter PCB 24 Splits and Multi Splits = High or low pressure trip. If you see fault code CH07 only type 7 in your text message CH57 Comms error between outdoor main PCB and inverter PCB. If you see fault code CH07 only type 7 in your text message CH16 no such fault code Text 1, 2 or 3 digit fault code number only.

Disconnect from PCB and measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. Disconnect from PCB and measure resistance. 10 kOhm at 10C and 4 kOhm at 30C 126 Sub 1 outdoor unit Subcool inlet sensor fault. Check comms wiring and power to all outdoor units 157 Sub 3 high pressure sensor fault. Lg Mini Split Error Codes Check coil and filters are clean and free from debris, and airflow is OK.

Low at 1 bar High at 35 bar check pressures. Lg Air Conditioner Error Codes Pdf Disconnect from PCB measure resistance 237 kOhm at 20C and 168 kOhm at 30C. 42 Low pressure sensor fault. If OK change outdoor inverter PCB CH29 no such fault code Text 1, 2 or 3 digit fault code number only. http://errorcodeairconditioning.blogspot.com/2010/10/lg-fault-code.html All rights reserved Last updated - 11/10/2016 Posts Comments Home Software Service Manual Compressor Catalog HVAC Handbook Thursday, October 21, 2010 LG Fault Code 7:29 AM Diposkan oleh James

Lift the front cover of the air con, on the right hand side there is a button or a hole which has a button inside which you can press which is Lg Inverter Air Conditioner Troubleshooting Faulty indoor or outdoor PCBs. Get Air Conditioner, Air Conditioner price list and best Air Conditioner in Delhi at Lowest price. If OK replace PCB, if not replace sensor 48 Split/Multi Split = Outdoor unit discharge and air sensor both unplugged.

Lg Air Conditioner Error Codes Pdf

If not replace sensor. 03 Remote controller comms error.

Check pressures, check coils, and filters are clean check for OFN in system pipework CH35 Excessive low pressure drop under 1 Bar at LP sensor. Lg Inverter Air Conditioner Error Codes Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar 44 Outdoor unit air sensor fault. Lg Air Conditioner Error Code Ch 05 Varun Khattar 10.141 görüntüleme 0:35 LG Refrig FUSE Repair Part2 - Süre: 7:48.

LowOutdoor Status = OffError Code = 65Contents = Heat Sink Sensor (Open/Short)LED01G = 6 times(Red) LED02G = 5 times(Green)Case Of Error = Open / Short circuitOutdoor Status = OffError Code = http://globalinfoindex.com/error-code/lg-neo-plasma-error-code-ch-5.php replied5 years ago. Disconnect from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C. HighLED01G = 6 times(Red) LED02G = 2 times(Green)Case Of Error = Heat Sink Temp. Lg Air Conditioner Error Code Ch 10

Disconnect from PCB measure resistance 237 kOhm at 20C, 168 kOhm at 30C. CC RAC Product = EEPROM Sum Check Error, text 60 for help. Cd RAC Product = Click here to watch major projects and company news View gas regulations View our sales website Mitsubishi Electric Super High COP Inverter Heat-pump Air Conditioning unit Portable Server Room LG LXA1210ACL Air... Check This Out Pipe Sensor Temp.

Replace PCB CH10 RAC Product: Compressor discharge sensor fault. Lg Vrf Error Code List View Most Popular Air Conditioners Related Question How do I get hot air to blow from LG Plasma air con model no LSNH1264DM0 LG LS186HE 18,500 BTU SingZone WaMounted Cool/Heat Pump MITSUBISHI CITY MULTI FAULT CODE FAULT CODE = 403 R22 = x R407c = x R410A = x LOSSNAY = - DESCRIPTION = Comms fault between boards - check inverter error

Apr 06, 2016 | LG LSC121PMA Split System Air Conditioner 1 Answer LG neo plasma error code It means the lid is open OR it has a short circuit.

Disconnect from PCB and measure resistance. Check system pressures for non-condesables CH62 Inverter over 85C. Panasonic Error Code Diagnosis display = H00 Abnormality / Protection control = No abnormality detected Abnormality Judgement = Emergency operation = Norma... Lg Air Conditioner Error Code Ch 02 Check pressures, check for non condensables, check heat exchanger coil is free from debris 145 Sub 2 excessive rise of high pressure.

If OK replace PCB, if not replace sensor 166 Sub 3 outdoor unit liquid pipe sensor fault. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor 02 Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Disconnect from PCB and measure resistance. 10 kOhm at 10C and 4 kOhm at 30C 168 Sub 3 outdoor unit Subcool outlet sensor fault. this contact form Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C.

Jan 09, 2008 | LG LS-L1210CL Mini Split Air Conditioner Not finding what you are looking for? If OK, mechanical failure. 152 Excessive discharge temperature rise 105C Sub condenser 2 standard compressor. Disconnect from PCB measure resistance 237 kOhm at 20C and 168kOhm at 30C. veloseped10 33.084 görüntüleme 3:59 LG Air Conditioner Single Split Heat Cool Professional Installation - Süre: 12:58.

Check drain pan is empty, check pump is working OK. If correct voltage appears at all three phases, swap any two to cure the fault 142 Communication error between Main and Sub outdoor units. Generated Thu, 01 Dec 2016 01:03:48 GMT by s_ac16 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection Indoor unit faultsFascia LED’s REDFascia LED’s GREENContentsCase of ErrorIndoor Status CH01 or C1None1 FlashIndoor Air Sensor (Open/Short)Open or Short CircuitOff CHO2 or C2None2 FlashInlet Pipe SensorOpen or Short CircuitOff CH03 or

Disconnect from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C. LTDPokolenie 14.575 görüntüleme 1:12 Harga AC LG 1/2, 1, 3/4, 2, 2.5 PK Terbaru Desember 2013 - 2014 - Süre: 1:51. If OK either inverter or main PCB defective RAC Indoor unit BLDC Fan problem.

You can change this preference below. If OK replace PCB, if not replace sensor CH46 Outdoor unit suction sensor fault. If there is a communication error fault CH05, will appear within 5 minutes of powering up the system. Check system pressures for non-condesables 62 Inverter over 85C.

Yükleniyor... Çalışıyor... Disconnect from PCB measure resistance 237 kOhm at 20C, 168 kOhm at 30C. Multi V: 1 Vdc = 8 bar up to 2.5 Vdc = 37 bar 158 Sub 3 low pressure sensor fault. Yükleniyor...

Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4 CH06 Indoor unit coil sensor fault. If the tests in 2 and 3 above show the correct voltage, the fault lies in the interconnecting cable.